In order to help with any issues
that arise either during or shortly after installation of a Magiglo gas
fire, this section covers Installation Frequently Asked Questions.
Where technical advice is given, is not intended as a substitute for a site visit by a competent person.
All installations must comply with the relevant installation
instructions and regulations.
A. This is a common complaint to Magiglo but normally turns out to be lack of gas pressure.
Please carry out following test prior to ringing Technical Dept.
Manual Control:- Remove cover from gas valve, place gas gauge on test nipple marked in and light pilot. Turn control knob to main burner observing pressure reading. A drop of more than one mbar denotes lack of gas supply. This will also cause pilot to shrink.
Remote/TS Mertik Gas Valve: - Carry out as above test using 1st test point on left side of gas valve. There is no need to remove knobs or cover.